HIO0308 - HIOKI BT6075 HIGH PRECISION BATTERY TESTER
|
|
High Precision Battery Tester, Beginning and end-of-line Test, for High-Precision Cell Grading
Our Part No. BT6075
Mfr. Model BT6075
The Hioki Precision Battery Tester BT6075 is designed for OCV/AC-IR testing of high-capacity EV battery cells with low internal resistance.
Voltage display: 7-1/2 digits
±0.0012% rdg. ±11 µV
Max. DCV resolution: 1 µV
Max. AC-IR resolution: 0.01 µΩ
Excellent resistance measurement resolution and accuracy
No additional... |
Battery testers
|
|
|
|
HIO0307 - HIOKI BT6065 HIGH PRECISION BATTERY TESTER, OCV/AC-IR TEST FOR CELL SCREENING
|
|
Our Part No. BT6065
Mfr. Model BT6065
The Hioki Precision Battery Tester BT6065 is designed for OCV/AC-IR testing of high-capacity EV battery cells with low internal resistance.
Voltage display: 6-1/2 digits
±0.002% rdg. ±20 µV
Max. DCV resolution: 10 µV
Max. AC-IR resolution: 0.01 µΩ
Excellent resistance measurement resolution and accuracy
No additional voltmeter is needed for OCV/IR testing
Stable measurement with the MIR mode (mutual interference... |
Battery testers
|
|
|
|
HIO0041 Hioki 3554 Battery Tester-Japan
|
|
Re-designed circuit for super resistance to noise
Store up to 4800 sets of battery data in internal memory and manage records on your PC
Auto-hold and Auto-store functions make measurement and recording simple and hands-free
Strengthened (and user-exchangeable) probe tip means less chance of breakage and more constant workflow
|
Battery testers
|
|
|
|
HIO0310-HIOKI FT3424 LUX METER - JAPAN
|
|
Hioki FT3424 - Light Meter with Broad Coverage from Low to High Illuminance
FT3424 Light meter
Compatible with LED lighting
Complies with DIN 5032-7:1985 class B and JIS C 1609-1:2006 general AA class
Timer hold function lets you make measurements in remote locations while avoiding the effects of shadows and reflections
Save up to 99 measured values in the instrument’s internal memory and transfer them to a computer later for improved work efficiency
Light... |
Light/Lux meters
|
|
|
|
HIO0004-Hioki 3282 Frequency Clamp On Hi-Tester (TRMS)
|
|
From Japan
AC Current/Voltage, Frequencies, Resistance, Conduction check, Temperature (probe sold separately)
Wave peak value, Waveform distortion check
Auto-power off to prevent the power from being left on
Non-fuse type protects up to 600 V AC
1000 A AC Ø 46 mm
|
Clamp meters
|
|
|
|
Hioki Clamp meters (Malaysia)
|
|
All range of Hioki clamp from Japan. |
Clamp meters
|
|
|
|
Help
|
|
This section contains information about purchasing items from our company. |
About KKInstruments
|
|
|
|
HVP120-PDSK01 PDSURVEYOR HANDHELD PARTICLE DISCHARGE SURVEYING TOOL-MADE IN UK
|
|
PDSurveyor™ Product Overview
The PDSurveyor™ is HVPD's original handheld PD surveying tool. It is the 'first-line of defence' for the detection of partial discharge activity in On-line medium voltage (MV) power cables and plant in the voltage range 3.3 kV to 45 kV. The unit enables the user to carry out rapid (10 - 20 seconds per plant item), 'look-see' insulation condition testing through a unique combination of measurement technology, incorporating three types of PD sensor: HFCT, TEV and... |
Partial Discharge (PD) Tester
|
|
|
|
HVP110-PDS AIR HANDHELD PD SURVEYING TOOL (PARTICLE DISCHARGE TESTER)-MADE IN UK
|
|
Product Overview
*New* - The PDS Air™ partial discharge surveying tool from HVPD represents the very latest in handheld PD test technology. Incorporating a digital TEV-dB display and external airborne acoustic probes, the test unit provides the 'first-line of defence' for the early detection of PD activity in MV cables and plant from 3.3 kV to 45 kV. Rapid, 'look-see' insulation condition testing is possible through the unique combination of three PD measurement technologies: HFCT, TEV and... |
Partial Discharge (PD) Tester
|
|
|
|
HUAT001B-DT160 (16 CHANNELS THERMOCOUPLE VERSION) PORTABLE MULTIFUNCTIONAL DATALOGGER
|
|
*THERMOCOUPLE(TEMP) INPUT ONLY*
Product Description
This series product is a portable paperless data logger. With 8/12/16 channel universal input and thermocouple input function, it can detect thermocouple, RTD, NTC, DC current, DC voltage, frequency, pulse count and other signals at the same time, and the collected data can be vividly displayed through various forms such as digital interface, bar graph interface, real-time curve, etc. The device has rich peripheral interfaces such as USB, TF... |
Datalogger/Recorders
|
|
|
|
HUAT001A-DU160 (16 CHANNELS UNIVERAL VERSION) PORTABLE MULTIFUNCTIONAL DATALOGGER
|
|
Product Description
This series product is a portable paperless data logger. With 8/12/16 channel universal input and thermocouple input function, it can detect thermocouple, RTD, NTC, DC current, DC voltage, frequency, pulse count and other signals at the same time, and the collected data can be vividly displayed through various forms such as digital interface, bar graph interface, real-time curve, etc. The device has rich peripheral interfaces such as USB, TF card, RJ45, WIFI, etc. It is a... |
Datalogger/Recorders
|
|
|
|
HIO0194 - HIOKI LR8431-20 10 CHANNEL MEMORY HILOGGER (WITH STANDARD ACCESSORIES ONLY)
|
|
10 Channel Memory HiLogger
Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, pulse or rotation signals, providing complete isolation between channels and strong noise resistance . The LR8431 logs data at 10ms speeds across 10 channels simultaneously, and features a bright color LCD for crystal clear waveform displays.
The LR8431-20 delivers improved thermocouple measurement accuracy and reference junction compensation... |
Datalogger/Recorders
|
|
|
|
HOB301-UX120-017 4-CHANNEL PULSE, EVENT, STATE AND RUN-TIME DATA LOGGER (LOGGER ONLY)
|
|
The HOBO UX120 Pulse Logger is a highly versatile, 4-channelenergydata logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates. The HOBO UX120 Pulse Logger is available in astandard memory model (UX120-017)capable of 500,000 measurements and anexpanded memory version... |
Datalogger/Recorders
|
|
|
|
HOB901/HOB902 SOFTWARE KIT FOR WINDOWS/MAC (INCLUDES SOFTWARE AND CABLE)
|
|
This totally new HOBOware for Windows supports all HOBO U-Series loggers, including HOBO Water Level and HOBO Pendant loggers; Onset's HOBO Weather Station and HOBO Micro Station; and incorporates valuable new capabilities such as scaling data to sensor units and saving graphs so they can be recalled and used in the future. In addition, HOBOware Pro includes Post-Processing Assistants, for Growing Degree Days and Grains per Pound. The USB Interface cable is included with the HOBOware... |
Datalogger/Recorders
|
|
|
|
HOB402 U12-012 TEMP/RH/LIGHT/1 X EXTERNAL ANALOG DATA LOGGER (LOGGER ONLY)
|
|
The HOBO U12 Temp/RH/Light/External is a four-channel data logger that provides temperature, relative humidity, relative indoor light level measurements and accepts one external input.
>> Temperature, Humidity, Light with 1 External Analog Input for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2... |
Datalogger/Recorders
|
|
|
|
HOB906 U-DT-1 U SHUTTLE DATA TRANSPORTER/DATA COLLECTOR
|
|
The pocket-sized Shuttle provides a convenient way to readout and relaunch many of the HOBO data loggers and bring the data back to your host PC. The HOBO Shuttle works with the HOBO U-series loggers and HOBO Weather Stations and Micro Weather Stations.
Features
4 MB non-volatile memory, allowing you to readout many loggers (504 loggers with 8K memory - some Pendant Loggers) (63 loggers with 64K memory - most U-Series Loggers) (7 loggers with 512K memory - weather/micro stations and... |
Datalogger/Recorders
|
|
|
|
HOB904 CABLE-ADAP10 0-10V INPUT CABLE
|
|
0 to 10 Volts DC External Input Cable>> Input Range: 0 to 10 Volts DC >> Impedence: 20 KΩ with 0.6 mV Resolution >> Cable: 13mm (0.5") Tinned Braided Wire Leads >> Cable Length: 1.9 Meters (6.3 feet) >> Indoor Use Only
|
Datalogger/Recorders
|
|
|
|
HOB903 CABLE-4-20MA 4-20MA INPUT CABLE
|
|
4-20mA Input Cable >> Cable for Connecting Sensor with 4-20mA Output to Logger >> Length: 18.5" >> Use in Outdoor and Indoor Environments |
Datalogger/Recorders
|
|
|
|
HOB404 U12-013 TEMP/RH/ 2 X EXTERNAL ANALOG INPUT DATA LOGGER
|
|
>> Temperature, Humidity with 2 External Analog Inputs for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2 (Light) Operating Ranges >> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18 Hours Adjustable by User >> 1 Year Replaceable Battery Life... |
Datalogger/Recorders
|
|
|
|
HOB403 U12 Outdoor/Industrial Data Logger with 4 External Channel Inputs
|
|
>> Weatherproof Enclosed Logger with 4 External Inputs for Measuring and Recording Multiple Parameters >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature) and 0 to 95% RH (Humidity) Operating Range >> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18 Hours Adjustable by User >> 1 Year Replaceable Battery Life >> Requires HOBOWare... |
Datalogger/Recorders
|
|