GNA3204-AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 Thermometers
GNA3203-AIR/WATER COOLING JACKET FOR IR-40, IR-80, IR-80-H, 10-IRMAN, 6-IRMAN Water-cooling jacket is to use under the high temperature environment. It makes infrared thermometer cool down and working properly. It can be applicable to IR-40, IR-80, IR-80-H, SS-100, 2IGA-100 Thermometers
GNA3202-Air Purge Jacket Air purge removes dust around infrared thermometer. It can be applicable to IR-20, IR-20-4W, IR-21, IR-40, IR-80, IR-80-H, 6-IRman, SS-100, 2IGA-100 Thermometers
GNA3201-L-SHAPE ANGLE ADJUSTABLE BRACKET Bracket is to fix infrared thermometer. Thermometers
GNA3200-COMPACT MULTI ANALOG INPUT INDICATOR Multi-input indicator  has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm Thermometers
GNA3108A-10-IRMAN -20~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Measuring range -20~1000℃,Spectral range 8~14㎛,optics 40:1,emissivity 0.10 ~ 0.99 adjustable, output 0~20mA/4~20mA/1~5V& 3m cable. PC software provided Thermometers
GNA3107A-6-IRMAN -20~600C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the amount of infrared energy emitted from object and transmits standard current output signal (4~20mA) or RS-485 communication output signal. Also, it transmits relay contacts for alarm signal. As 6-IRman is composed of infrared sensor head & LCD display with keypad, you can check the temperature value in real-time at the installation site. You can measure the temperature ranged from -20 to max. 600℃... Thermometers
GNA3106A-IR-204v2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA). It can measure from 0 ℃ to maximum 400℃ in the distance of 10:1 D:S (Distance to Spot). Emissivity is 0.95 (fixed). Thermometers
GNA3105A-IR-214V2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer  non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 0 ℃ to maximum 400℃ in the distance of 12:1 D:S(Distance to Spot). Thermometers
GNA3104A-IR-404V2 0~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-40 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from -20 ℃ to maximum 1000℃ in the distance of 40:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
GNA3103A-IR-80-H4V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-80-H non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
GNA3102A-IR-804V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Non-Contact Fixed Infrared Thermometer IR-80 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. IR-80 is composed of sensor & controller. The measurement temperature displays... Thermometers
GNA3101A-2IGA-1004V2 400~1200C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Two color Non-Contact Fixed Infrared Thermometer 2IGA-100 two color(InGaAs/InGaAs) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 400 ℃ to maximum 1200℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
GNA3100A-SS-1004V2 800~2400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA Two color Non-Contact Fixed Infrared Thermometer SS-100 two color(Si/Si) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 800 ℃ to maximum 2400℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. Thermometers
RIX1100+TST0513+RIX1255A KIT K, J, E, T, B, R, N, S, C THERMOMETER DELUXE SET W CASING COMPLETE WITH SUPER THIN PROBE *Design in Japan. Assembled in Taiwan for Japanese Market.Input TypesK, J, E, T, B, R, N, S, C nine thermocouple types; IP66 water-proof & dust-proof.Data-Logging up to 16000 readings x 2 CH; with Real time recording.Multiple graph/Data table view,Export to MS Excel  .Max/Min/Avg/Hold ; Hi/Lo Alarm Functions.Dual thermocouple inputs; Large LED back-light.Both USB and RS-232 interface cable, with software.IP66, CE and RoHS approved. Thermometers
TEN930B-TM-82NV2 DUAL INPUT DIGITAL K TYPE THERMOMETER W MAX/MIN VALUE - Dual LCD 5-digit display.- Single input (TEN930A), dual input (TEN930B).- Auto power off with disable function (15 minutes).- Max/Min/Avg/Hold function keys.- °C/°F switchable.- REL, OFFSET, T1-T2 (TEN930B) . Thermometers
CEN0021-500V2 PRINTING TEMPERATURE GRAPHIC RECORDER (K,J/GRAPHIC PRINTER/ DATALOGGER / USB) a temperature graphic recorder with built in printer. The printer can output text format so that the users can get the exact reading, or it can output graphic format to give the whole changing tendency in one image. The sample period and the graphic scale are programmable so the users can get the exact result as expected. Besides the printer function, this unit is also a datalogger. The recorded data can be logged to a computer for further analysis. Thermometers
TEN930A-TM-80NV2 DIGITAL K TYPE THERMOMETER W MAX/MIN VALUE - Dual LCD 5-digit display.- Single input (TEN930A), dual input (TEN930B).- Auto power off with disable function (15 minutes).- Max/Min/Avg/Hold function keys.- °C/°F switchable.- REL, OFFSET, T1-T2 (TEN930B) . Thermometers
TEN930-YF-160A-V2 ECONOMICAL DIGITAL K TYPE THERMOMETER Product Description - 3 1/2 Digits LCD maximum reading of 2000- ºC/ºF selectable- Type "K" thermocouple- Switchable resolution 0.1º / 1.0º- Data hold / Offset setting Thermometers
IRI1100-VERSALOG 6 CHANNEL DATALOGGER (4 CHANNEL THERMOCOUPLE INPUT/2 CHANNEL PT100) WITH SCREEN/SOTWARE See product photo for details *From UK*4 x J,K,T,E,R,S,N Thermocouple inputs*2 x 3-wire PT-100 inputs*Display and log all 6 channels simultaneously with graphs*SD card recording*Supplied with a 5 V DC power supply, stand, and 4 GB SD Card. It can also be powered by 2 x AA batteries (not included). Thermometers